Higher Heat Resistant Canned Motors , Types U & X
Two different types of non-cooled higher heat resistant canned motors are available in addition to regular canned motors of which max allowable liquid temperature with no cooling is around 130 deg C / 266 deg F. The special motor insulation with non-organic materials is the key for types U and X.
Types U and X are the best featured in handling high temperature liquids such as Heat Transfer Oils, Hot Water and High Melting Temperature Chemicals with un-comparable easiness. Types U and X need no cooling providing customers with considerable energy and utility savings in high temperature pumping.

	
		◆ Type U
	
		
		
		
	
	
		
			| 
				Temp max | 
			
				446 ℉ | 
			
				230 ℃ | 
		
		
			| 
				Output max | 
			
				214 HP | 
			
				160 kW | 
		
	
	
		◆ Type X
	
		
		
		
	
	
		
			| 
				Temp max | 
			
				644 ℉ | 
			
				340 ℃ | 
		
		
			| 
				Output max | 
			
				80 HP | 
			
				60 kW |